EasyManua.ls Logo

powersoft X8 - Firmware Issue - Latest Version; Thermal Limiter; Limiter Issues on AMP Modules

powersoft X8
45 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
36
X8 | SERVICE MANUAL
Firmware Issue - latest version
Thermal Limiter / Limiter issues on the AMP Modules
Replace thre DIGI+ADLINK
Boards
Perform the SD Card
Recovery procedure and
turn the unit on
PASS
FAIL
Resolved
Resolved
Update the unit’s
Firware via Armonia
or through the USB
Pen Drive procedure
Update the unit’s
Firware via Armonia
or through the USB
Pen Drive procedure
Update the unit’s
Firware via Armonia
or through the USB
Pen Drive procedure
Unplug the Unit’s Input and Output connectors
Install the .pam
default parameters and
restart the unit
Perform the SD
Card Recovery
procedure
Replace the Flat Cables
Place the
suspected faulty AMP
Module in a different
slot and repeat the
procedure
The issue
persists on the
same channel
The issue
moves to the
new channel
Replace
the
DIGI+ADLINK
Boards
Replace the
AMP Module
FAIL
OK
FAIL
OK
Update the unit’s
Firware via Armonia
or through the USB
Pen Drive procedure