This menu shows an overview of enabled and disabled outputs.
PO1 220V relay outputs is fixed for Bleed valve
FO1 & FO2 CRT relay outputs are fixed for Biocide
A and Biocide B
FO3 CRT relay output could be used for Inhibitor
or Dosing.
FO4 CRT relay output could be used for Disper‐
sant or Dosing.
AO1 & AO2 are outputs used for transfer or
dosing.
PO1 for bleed valve control is enabled by default. The bleed valve
can be controlled volumentric or depending on the conductivity.
Fig. 48: Menu FO1 and FO2 relays
FO1/FO2 Biocide
A/B
Enables/disables the Biocide A/B relay.
Operating mode For the operating mode Timer, Oxidant or
Timer & Oxidant can be selected.
Pre-bleed mode For pre-bleed mode duration and setpoint can
be selected.
Enable bleed
lockout
Enables/disables the bleed lockout.
Tank low level
detection
Digital inputs configured as tank level can be
assigned to this relay.
Pump flow rate The calculation of tank level requires the pump
flow rate.
Tank volume The calculation of the tank level requires the
tank volume.
Enable compute This button activates the tank volume and
pump flow rate.
PO1 relay
FO1 and FO2 relays
General Menu
45