BALANCING THE LOAD CELLS Balancing the load cells
Cubiscan 325 Service Manual 25
12. When all four corners read approximately the same
weight, the load cells are balanced.
13. Replace the load cell summing box lid and screw it
into place.
14. Slide the center cover back into place and tighten
the thumb screws.
15. When everything has been replaced and the load
cells have been balanced, you need to recalibrate
the scale. For instructions on calibrating the scale,
see “Scale Calibration” on page 13.