70©2006 Sunrise Medical
QUICKIE ELECTRONICS SECTION
General Wheelchair Test
Complete the following test to verify Time On, Time
Driven, and Internal Control Box Temperature (Motor
Controller).
Connect the Quickie iQ or HHP to the wheel-1.
chair.
Turn on the wheelchair2.
If using the HHP, select Monitor, then System, 3.
then Others. ( g 2.23.30)
If using the Quickie iQ, select Monitor Parameter, 4.
then Motor Controller, then Others. ( g 2.23.31)
Others
+ + -
Time On 3 h
Time Driven 0 h
Int c/box Temp 22 deg
If using the HHP, record Time On, Time Driven, 5.
and Internal Control Box Temperature. If using
Quickie iQ record Time On, Time Driven, Internal
Control Box Temperature, and Motor 1 and Motor
2 Temperature
Refer to the following notes:6.
Internal Control Box Temperature and Motor
Temperate are valuable information for trouble-
shooting Thermal Rollback Issues.
Motor maximum temperatures are approximate-
ly 100 degrees C.
Time On and Time Driven are important values
to record in case issues are reported after re-
pairs are completed on the wheelchair.
Fig 2.23.30
Fig 2.23.31