Technical Specifications
WinLink User and Installation Guide Version 1.750 2-25
Technical Specifications
Air Interface
WinLink is available in several different frequency band ranges that
comply with ETSI, FCC and IC regulations.
Frequency Bands and Channel Bandwidth
Table
2-2: Configurable Transmission Options
5.850-5.950 GHz
5.725-5.850 GHz
5.470-5.725 GHz
5.150-5.350 GHz
4.940-4.990 GHz
2.500-2.700 GHz
2.400-2.4835 GHz
Frequency Bands
2.300-2.340 GHz / 2.310-2.485 GHz
Channel Bandwidth 5MHz, 10MHz and 20MHz (5MHz Resolution)
Transmit Power Configurable (max: 23dBm)
Duplex Technique TDD (Time Division Duplex)
Sensitivity (dBm) @BER <10e-11
(20MHz)
-87 -84 -80 -79 -73 -66 -62
Rate (Mbps) 9 12 18 24 36 48 54
Modulation@OFDM (Adaptive) BPSK QPSK 16QAM 64QAM
Rates and Services Supported
WinLink systems offer a variety of channel bandwidths, maximum
throughput and supported services.
Table
2-3: Rates and Services Supported
Channel
Bandwidth
5 MHz 10 MHz 20 MHz
Maximum
Throughput
5.4 Mbps 9.9 Mbps 18 Mbps
Supported
Services
1 E1/T1 +
Ethernet
2E1s or 4T1s +
Ethernet
4 E1/T1 + Ethernet
Ethernet Latency 8 msec 6 msec 3 msec

Table of Contents

Other manuals for Radwin WinLink 1000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Radwin WinLink 1000 and is the answer not in the manual?

Radwin WinLink 1000 Specifications

General IconGeneral
BrandRadwin
ModelWinLink 1000
CategoryWireless Access Point
LanguageEnglish

Related product manuals