Configuring the Site
WinLink User and Installation Guide Version 1.750 5-93
Æ To configure the Jitter Buffer:
1. In the Main menu click the Link Configuration button.
2. Run the Configuration wizard (see
Figure
5-1
).
3. On the Services screen, select the TDM Jitter Buffer tab:
Figure
5-18: Jitter Buffer Configuration
4. Choose the desired values for HQ and Remote Site.
After setting the new value, the user must evaluate the expected
quality. During the evaluation the ETBE bar is displayed.
5. Click Next > to perform the change or < Back to cancel the
change.
Extra caution should be use when decreasing the value, since the
service quality might be affected in the case of interference. In cases
of asymmetric interference, the jitter buffer can be set to different
values per site. In such cases the latency will also be asymmetric.
Cautio
n