Configuring the Site
WinLink User and Installation Guide Version 1.750 5-97
Setting External Alarm Inputs
The IDU-C has two external alarm inputs in the form of dry-contact
relays. The Alarm interface is located on the front panel of the IDU-C
and is a 9-pin D-type female connector, see IDU-C Alarm Connector,
Appendix A: Wiring Specifications for the pinout. The user enables or
disables
each of the alarms and can configure the text that appears in
the alarm trap. The ODU sends the alarm within less than a second
from actual alarm trigger.
Æ To set the external alarm inputs:
1. Open the Site Configuration Alarms configuration by clicking
Configuration > Advanced.
Figure
5-21: External Alarm Configuration
2. Enter a description of the alarms in the fields.
3. Click Apply to save.