Link Configuration Wizard
WinLink User and Installation Guide Version 1.750 5-80
Transparent/Transparent
WinLink™ regenerates the clock from line clock side to Tx
clock on the opposite side of the link.
Loop time/Recover
The local unit receive clock is the transmit clock on both sides
of the link.
Recover/Loop time
The remote unit receive clock is the transmit clock on both
sides.
Internal/Recover
The local unit internal oscillator generates the clock while the
remote unit recovers this clock.
Recover/Internal
The remote unit internal oscillator generates the clock while
the local unit recovers this clock.
Note:
The Line code option is used with T1 Systems.
Table
5-1: TDM Clock Modes
Unit Clock Mode User Equipment Side
Local Unit Remote Unit HQ side Branch side
1 Transparent Transparent Internal/Recover Internal/Recover
2 Loop Time Recover Internal Recover
3 Recover Loop Time Recover Internal
4 Internal Recover Recover Recover
5 Recover Internal Recover Recover
Setting the T1 Line Code
The T1 line code can be set as B8Zs or AMI in the TDM Parameters
dialog box.
The default is B8ZS.
Note:
This dialog box is available only when TDM service was selected in the
previous Services dialog box.