Setting the Clock Configuration
WinLink User and Installation Guide Version 1.750 3-53
link. The user equipment must be configured as described in the
following table.
Table
3-2: TDM Clock Modes
Unit Clock Mode User Equipment Side
Local Unit Remote Unit HQ side Branch side
1 Transparent Transparent Internal/Recover Internal/Recover
2 Loop Time Recover Internal Recover
3 Recover Loop Time Recover Internal
4 Internal Recover Recover Recover
5 Recover Internal Recover Recover
Transparent/Transparent
WinLink transparently regenerates the clock from line clock
side to Tx clock on the opposite side of the link.
Loop time/Recover
The local unit receive clock is the transmit clock on both sides
of the link.
Recover/Loop time
The remote unit receive clock is the transmit clock on both
sides.
Internal/Recover
The local unit internal oscillator generates the clock while the
remote unit recovers this clock.
Recover/Internal
The remote unit internal oscillator generates the clock while
the local unit recovers this clock.
8.
Note:
The Line code option is used with T1 Systems.