EasyManua.ls Logo

Rasilient PixelStor 5000 - Drive Failure; Unhealthy RAID Disk Group

Rasilient PixelStor 5000
161 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Hardware Installation
PixelStor 5000 User Manual
Rev. 1, May 2013
5-84
5.2.5 SAS Cable Disconnect (Lost Connection to Expansion Enclosure)
If a cable fails or is accidentally disconnected, the system will react as if the SAS IO Module
failed. (See 5.2.4 “SAS IO Expander Failure” in previous section)
Corrective action:
Dual Controller - the system will fail over and the controller with healthy a SAS IO
connections will take over all the disks without disruption to data access. The
administrator can reconnect the SAS cable and the system will automatically fail-back to
regain redundancy.
Single Controller - all connected expansion enclosures (and drives) will become
unavailable. The administrator will need to reconnect the SAS cable and do a Disk
Group Restore to reactivate all the disk groups brought off line by the failure.
5.2.6 Drive Failure
If a one drive fails in a RAID 1/5/10 DG, or two drives in a RAID 6 DG, the DG will go into
degraded mode. If a global spare is present in the system, the spare will be automatically be
added to the DG and a rebuild of the DG will be initiated. (Note: RAID 0 by definition has no
protection and therefore cannot be rebuilt.)
Corrective action:
No Spare Replace the failed drive and the system will automatically start a rebuild of
the DG. (It is recommended that a global spare is always installed in the system to
insure data availability.
Spare Present - Replace failed drive. This will automatically be added to the system as a
global spare.
5.2.7 Unhealthy RAID Disk Group
If a RAID Group experiences a drive fault that is unrecoverable, the System Health Alert is
triggered. For example, this can happen if a RAID 0 Disk Group experiences a drive failure or a
RAID 5 Disk Group experiences two consecutive drive failures.
Corrective action:
Recover the Disk Group from a recent back-up.

Table of Contents