19 | Care (chemical storage)
Original instructions for use 163 / 188
Unsuitable care products
Do not use any of the following products to clean the unit or its functional
components or accessories:
n
Scouring agents
n
Hydrochloric acid, lye, sulphurous substances, or other oxygen-consuming
agents
n
Undiluted alcohol, methanol, or solutions such as acetone, benzene, toluene,
or xylene
n
Oven cleaner or grill cleaner
n
Pot scrubber with steel wool
n
Steel wool
n
High-pressure cleaning jets
n
Sharp or pointed tools
19.3 Care intervals WA62
Care interval Functional components
Daily
n
Cooking cabinet
n
Cooking cabinet seal
n
Cooking cabinet door
n
Drip pan and discharge spout
n
core temperature probe
n
Accessories
n
Hand shower
Weekly
n
Unit exterior surfaces
n
LED cover
n
Control panel
n
Plastic parts
Monthly
n
steam nozzle
n
Cleaning hatch
At minimum, the functional components must be cleaned in accordance with the
care interval; they can be cleaned more frequently if necessary.