9 | Finishing
Original instructions for use 73 / 188
9.2 Setting the banqueting plate weight
NOTE
To prevent material damage, insert the core temperature probe into the
ceramic tube on the right side of the mobile plate rack after loading.
Before starting the Finishing step, set how heavy an empty plate is. Based on this
information, the cooking system will adjust the cooking steps to ensure ideal
Finishing results and prevent moisture from condensing onto the plates.
1. Press this button:
2. Press this button: Cooking
3. Press this button: Banquet plate weight
4. Select one of the following values:
n
<750g
n
750g–899g
n
900g–1099g
n
>1100g