20 | Inspiration and help
172 / 188 Original instructions for use
Error report Cause Cooking possible
Service 34.64 The internal data
communication is faulty.
Yes
Service 34.400 The internal data
communication is faulty.
Yes
Service 41 The steam injection nozzle or
the steam injection pipe has
scale.
The steam injection
function is not
available.
Service 50 The real time clock on the
CPU is not initialised. Set the
date and time.
Yes
Service 51 The battery is defective. Yes
Service 52.1 The cooking cabinet lighting
is not working correctly.
Yes
Service 52.2 The cooking cabinet lighting
is not working correctly.
Yes
Service 72 The activation temperature
of a temperature probe has
been exceeded.
No
20.5 Error messages
20.5.1 Error messages heating steam generator
Error
message
Cause Cooking possible
Service 10 SC automation is malfunctioning. Yes
Service 11 The water intake for the steam
generator is malfunctioning.
Yes
Service 12 The water measurement system is
malfunctioning.
Yes
Service 13 Detection of the water level in the
steam generator is malfunctioning.
Only hot air mode is
available.
Service 20.8 Temperature probe defective. Only hot air mode is
available.
Service 28.4 Cooking cabinet temperature limit
exceeded.
Only hot air mode is
available.
Service 42.1 The water supply is malfunctioning. Only hot air mode is
available.