20.3.2 Querying service data
You can call up the service data in the settings. More information is available here:
Service [}129]
20.4 Problem resolution
You can swipe error messages aside if they appear while you are waiting for help.
The error messages will be minimized and shown on the side of the display as a
red symbol. Tapping that symbol will display the error message in original size
again.
Please contact your RATIONAL Service Partner regarding all error messages.
Always have your cooking system’s serial number and the installed software
version number at the ready. This information will be displayed in the error
message.
20.4.1 Notification centre
Error report Cause Cooking possible
Service 17 The unit model is incorrect. No
Service 29 The board temperature is
too high.
No
Service 31.1 The core probe in the
cooking cabinet is defective.
Yes, but you cannot
use the core probe.
Service 31.2 The core probe in the
cooking cabinet is defective.
Yes, but you cannot
use the core probe.
Service 34.16 The internal data
communication is faulty.
Yes