20 | Inspiration and help
Original instructions for use 173 / 188
Error
message
Cause Cooking possible
Service 43.1 The internal water supply is not
closing.
Only hot air mode is
available.
Service 46.1 The water supply is malfunctioning. Yes
20.5.2 Error messages for gas units
If your unit it connected to the gas supply, the following additional error message
could appear. For all error messages, please contact your RATIONAL Service
Partner [}170]. Always have the serial number of your unit ready.
Error report Cause Cooking possible
Service 32.1 The gas burner is faulty.
Close the shut-off valve on
the gas line.
No
Service 32.2 The gas burner is faulty.
Close the shut-off valve on
the gas line.
No
Service 32.3 The gas burner is faulty.
Close the shut-off valve on
the gas line.
No
Service 33.1 The gas burner is faulty.
Close the shut-off valve on
the gas line.
No
Service 33.2 The gas burner is faulty.
Close the shut-off valve on
the gas line.
No
Service 33.3 The gas burner is faulty.
Close the shut-off valve on
the gas line.
No
Service 34.32 The internal data
communication is faulty.
Yes
Service 60 The initialisation of the
ignition box is defective.
Switch the unit off and on
again. If the error is still
displayed, call your Service
Partner.
–