No. Message in display Meaning and possible cause
9 Application rate
Min. setting = 10 Max. setting = 3000
Reference to the value range of the application
rate
• The entered value is not permitted.
10 Working width
Min. setting = 12.00 Max. setting = 50.00
Reference to the value range of the working
width
• The entered value is not permitted.
11 Flow factor
Min. setting = 0.40 Max. setting = 1.90
Reference to the value range of the flow factor
• The entered value is not permitted.
12 Transmission fault. No RS232 connection An error has occurred during data transmission
to the control unit.
The data has not been transmitted.
14 Error by setting TELIMAT Alarm for the TELIMAT sensor
This error message is displayed if the TELIMAT
status is not detected for more than 5 seconds.
15 Memory full, Delete one private fertiliser chart A maximum of 30 fertilizer types are stored in
the memory for the fertilizer charts.
16 Approach drop point Yes = Start Safety request before the drop point is
automatically approached
• Drop point setting in the menu Fertiliser
settings
• Fast emptying
17 Error by setting drop point The drop point adjustment cannot reach the
specified target value.
• Fault, for instance with the power supply
• No position feedback
18 Error by setting drop point The drop point adjustment cannot reach the
specified target value.
• Blockage
• No position feedback
• Calibration test
19 Defect by setting drop point The drop point adjustment cannot reach the
specified target value.
• No position feedback
6. Alarm messages and possible causes
QUANTRON-A AXIS/MDS 5902662
103