No. Message in display Meaning and possible cause
50 Idle meas. impossible. EMC control
deactivated!
PTO speed not permanently stable
51 Hopper empty! The kg level sensor reports “empty.” The
entered value is undercut.
52 Error at hopper cover The position of the hopper cover could not
be reached.
Blockage
Defective actuator
53 Defect at hopper cover The hopper cover actuator cannot reach the
target value for the movement.
Blockage
Defective actuator
54 Change TELIMAT position! The TELIMAT position does not correspond to
the state notified by GPS Control.
72 Error at SpreadLight Power supply is too high; the operating lights
will be switched off.
73 Error at SpreadLight Overload
74 Defect at SpreadLight Connection error
Defective cable
Loose plug connector
93 This disc type requires a modification on the
TELIMAT device. Please follow the mounting
instructions!
Spreading disc S1 is installed and the machine
is equipped with TELIMAT. Spreading errors
possible during border spreading
This spreading disc type requires
conversion of the TELIMAT device.
94 Error at border spreading equip Alarm for the GSE sensor. This error message
is displayed if the GSE status is not detected
for more than 5 seconds.
6. Alarm messages and possible causes
QUANTRON-A AXIS/MDS 5902662
105

Table of Contents