Code ID Description Recommended Actions
523877 .13
SPI (serial peri-
pheral
interface)error.
A memory error has occurred while trying to use the
interface.
1. Cycle power to the machine.
2. If the error persists, contact your local Raven
dealer or the Raven Technical Service team.
523878 .0
Logic SW power
error.
Logic power input to the HDU is out of range. If the
error persists, contact your local Raven dealer or the
Raven Technical Service team.
523880 .0
CANpower
error.
The voltage of the 3.3 V CANpower rail is outside the
tolerance of the system.
523881 .0
Internal Vref
error.
Reference voltage of 3.3 V is not present (either high
or low).
1. Cycle power to the machine.
2. Contact a local Raven dealer for additional
assistance.
523882 .0
Vbatt voltage
error.
Battery voltage.
1. Cycle power to the machine.
2. Check the machine electrical system for issues.
3. Contact a local Raven dealer for additional
assistance.
523883 .13
Jumper pin
invalid.
The actuator type does not match the jumper
selection.
1. Ensure cable connections are properly seated.
2. Inspect the connectors near the SC1/HDU for a
jumper wire and check connection of the wire.
3. Contact a local Raven dealer for additional
assistance.
523884 .11 Valve fault.
The machine steering valve has indicated a fault.
1. Ensure cable connections are properly seated.
2. Cycle power to the machine.