EasyManua.ls Logo

Raven DirecSteer - Page 183

Raven DirecSteer
218 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Diagnostics and Troubleshooting
Code ID Description Recommended Actions
523892 .6
DB pwr (power)
current fail.
Unexpected amperage supplied to the double blocker
solenoid while auto-steering is not active.
1. Ensure cable connections are properly seated.
2. Check cabling for shorts or loose connections.
3. Check for supply voltage on the connections to
the machine steering valve.
523893
.5
DB gnd (ground)
current (mA)
low.
Amperage supplied to double blocker solenoid too
low.
1. Ensure cable connections are properly seated.
2. Check cabling for broken or frayed wiring.
3. Check for supply voltage on the connections to
the machine steering valve.
.6
DBgnd (ground)
current (mA)
high.
Amperage supplied to double blocker solenoid is too
high.
1. Ensure cable connections are properly seated.
2. Check cabling for shorts or loose connections.
523894 .6
DB gnd (ground)
current fail.
Unexpected amperage supplied to the double blocker
solenoid while auto-steering is not active.
1. Ensure cable connections are properly seated.
2. Check cabling for shorts or loose connections.
523895 .6
Sen pwr (sensor
power) current
(mA) high.
Amperage output from sensor (e.g. wheel angle
sensor, disengage sensor, etc.) is too high.
1. Ensure cable connections are properly seated.
2. Check cabling for shorts or loose connections.
523896 .6
Sen gnd (sensor
ground) current
(mA) high.
Amperage output from sensor (e.g. wheel angle
sensor, disengage sensor, etc.) is too high.
1. Ensure cable connections are properly seated.
2. Check cabling for shorts or loose connections.
523897 .0
Safety micro-
No communication to the safety micro.
169

Table of Contents

Related product manuals