RL78/G13 CHAPTER 11 A/D CONVERTER
R01UH0146EJ0100 Rev.1.00 509
Sep 22, 2011
11.6.3 Software trigger mode (scan mode, sequential conversion mode)
<1> In the stop status, the ADCE bit of A/D converter mode register 0 (ADM0) is set to 1, and the system enters the
A/D conversion standby status.
<2> After the software counts up to the stabilization wait time (1
μ
s), the ADCS bit of the ADM0 register is set to 1 to
perform A/D conversion on the four analog input channels specified by scan 0 to scan 3, which are specified by
the analog input channel specification register (ADS). A/D conversion is performed on the analog input channels
in order, starting with that specified by scan 0.
<3> A/D conversion is sequentially performed on the four analog input channels, the conversion results are stored in
the A/D conversion result register (ADCR, ADCRH) each time conversion ends, and the A/D conversion end
interrupt request signal (INTAD) is generated. After A/D conversion of the four channels ends, the A/D
conversion of the channel following the specified channel automatically starts (until all four channels are finished).
<4> When ADCS is overwritten with 1 during conversion operation, the current A/D conversion is interrupted, and
conversion restarts at the first channel. The partially converted data is discarded.
<5> When the value of the ADS register is rewritten or overwritten during conversion operation, the current A/D
conversion is interrupted, and A/D conversion is performed on the first channel respecified by the ADS register.
The partially converted data is discarded.
<6> Even if a hardware trigger is input during conversion operation, A/D conversion does not start.
<7> When ADCS is cleared to 0 during conversion operation, the current A/D conversion is interrupted, and the
system enters the A/D conversion standby status.
<8> When ADCE is cleared to 0 while in the A/D conversion standby status, the A/D converter enters the stop status.
When ADCE = 0, specifying 1 for ADCS is ignored and A/D conversion does not start.
Figure 11-22. Example of Software Trigger Mode (Scan Mode, Sequential Conversion Mode) Operation Timing
ADCE
ADCS
ADS
INTAD
ADCR,
ADCRH
A/D
conversion
status
ADCE is set to 1.
<1>
ADCS is set to
1 while in the
conversion
standby status.
ADCS is
automatically
cleared to
0 after
conversion
ends.
<2> <4> <2> <2>
<4>
<2><4>
A/D
conversion
ends.
<3>
ADCS is overwritten
with 1 during A/D
conversion operation.
<5>
Conversion is
interrupted
and restarts.
Conversion is
interrupted.
<3>
ADS is rewritten during
A/D conversion operation
(from ANI0 to ANI1).
<6>
<3>
ADCE is cleared to 0.
<8>
ADCS is
cleared to
0 during A/D
conversion
operation.
<7>
The trigger
is not
acknowledged.
The trigger
is not
acknowledged.
Conversion
standby
Conversion
standby
Conversion
standby
Conversion
standby
Conversion
standby
Data 1
(ANI0)
Data 2
(ANI1)
Stop
status
Data 1
(ANI0)
Data 1
(ANI0)
Data 1
(ANI0)
Data 1
(ANI0)
Data 2
(ANI1)
Data 1
(ANI0)
Data 1
(ANI0)
Data 2
(ANI1)
Data 2
(ANI1)
Stop
status
<R>
<R>
<R>