108
Error:
Delete File
Operation denied
IsdisplayedwhenalecannotbedeletedfromtheSDcardbecauseprinting/millingiscurrentlyunderway.
Can be caused by:
- M30
- the menu item "Delete File"
Error:
X-Axis
Home unknown
IsdisplayedwhentheX-axiscannotbemovedbecausethehomepositionisnotknown.
Can be caused by:
-themenuitem"PositionX"
Error:
X-Axis
Operation denied
IsdisplayedwhentheX-axiscannotbemovedbecauseprinting/millingiscurrentlyunderway.
Can be caused by:
-themenuitem"PositionX"
Error:
Y-Axis
Home unknown
IsdisplayedwhentheY-axiscannotbemovedbecausethehomepositionisnotknown.
Can be caused by:
-themenuitem"PositionY"
Error:
Y-Axis
Operation denied
IsdisplayedwhentheY-axiscannotbemovedbecauseprinting/millingiscurrentlyunderway.
Can be caused by:
-themenuitem"PositionY"
Error:
Z-Axis
Home unknown
Is displayed when the Z-axis cannot be moved because the home position is not known.
Can be caused by:
- the menu item "Position Z"
- the hardware button "up"
- the hardware button "down"
Error:
Extruder
Operation denied
Is displayed when the extruder cannot be moved because it is too cold.
Can be caused by:
- the hardware button "Extract"
- the hardware button "Retract"
- the menu item "Load Filament"
- the menu item "Unload Filament"
- the menu item "Position Extruder"
Error:
Align Extruders
Operation denied
Is displayed when the alignment of the two extruders cannot be started because:
- Printing is currently being performed
- Only one extruder is installed
Error:
Align Extruders
Temperature wrong
Is displayed when the alignment of the two extruders cannot be started because:
- The temperature difference between extruder 1 and 2 is too high
Error:
Determine PID
Temperature wrong
Is displayed when it is found during automatic determination of the PID values that the actual temperature is
getting too high.
Can be caused by:
- M303
Error:
Determine PID
Timeout
Is displayed when automatic determination of the PID values cannot be completed within 20 minutes.
Can be caused by:
- M303
Error:
Temperature Manager
Sensor Error
Is displayed when a temperature sensor error is found (= the sensor returns a temperature < -10 or > +300 °C).
Thermwaremustberestartedbeforethetemperaturesensorswillbeevaluatedagain.
Error:
Emergency Z Block
Is displayed when all other movements in Z-direction are blocked due to too-high DMS values.
ThermwaremustberestartedbeforemovementintheZ-directionispossibleagain.
Warning:
Emergency Pause
Is displayed when the current print/milling process has been paused due to too-high DMS values.
To continue printing/milling, push the "Continue" button.