H17
Color / flashing pattern
Significance (control unit status) Measures
Green Rexroth IndraMotion MTX control is ready for
operation
Observe information displayed at operator panel.
See also Application Description "Rexroth
IndraMotion MTX" and documentation "Rexroth
IndraMotion MTX Diagnostics Messages"
Yellow Rexroth IndraMotion MTX control is booting Wait for booting phase to end
Red Error Rexroth IndraMotion MTX control
In the case of errors during the booting proc‐
ess (approx. 30 s), an error code is displayed
at the operator panel.
Observe information displayed at operator panel.
If an error is present, generate log file "MtxaCri‐
tErr.log" on programming module by switching
off/on (storage location of log file: Program → root/
cf).
See also Application Description "Rexroth
IndraMotion MTX" and documentation "Rexroth
IndraMotion MTX Diagnostics Messages"
Flashing red Error Rexroth IndraMotion MTX control
Off Supply unit not switched on Check 24V supply at X18 and switch it on, if not
yet done
Fig.12-7: LED Displays H17
DOK-INDRV*-HCQ-T+HMQ-T-PR03-EN-P
Rexroth IndraDrive Drive Controllers HCQ, HCT
Bosch Rexroth AG 117/145
Commissioning, Operation, Diagnostics