3. For the IEC product standard used, the corresponding Chinese GB
standard must exist.
For the drive components by Rexroth described in this documentation, certifi‐
cation is not required at present, thus they are not CCC certified. Negative
certifications will not be issued.
4.2 Transport and Storage
4.2.1 Transport of the Components
Ambient and Operating Conditions - Transport
Description Symbol Unit Value
Temperature range T
a_tran
°C Supply units and drive con‐
trollers:
-25 … +70
Motors:
-20 … +80
Relative humidity % 5 … 95
Absolute humidity
g/m
3
1 … 60
Climatic category (IEC 721) 2K3
Moisture condensation Not allowed
Icing Not allowed
Fig.4-4: Ambient and operating conditions - transport
4.2.2 Storage of the Components
Damage to the component caused by long
storage periods!
NOTICE
Some components contain electrolytic capacitors which may deteriorate dur‐
ing storage.
When storing the following components for a longer period of time, operate
them once a year for at least 1 hour:
Converters and supply units: operation with mains voltage U
LN
Inverters and DC bus capacitor units: operation with DC bus voltage
U
DC
Ambient and operating conditions - storage
Description Symbol Unit Value
Temperature range T
a_store
°C Supply units and drive con‐
trollers:
-25 … 55
Motors:
-20 … +60
Relative humidity % 5 … 95
Absolute humidity
g/m
3
1 … 29
Climatic category (IEC 721) 1K3
Moisture condensation Not allowed
Icing Not allowed
Fig.4-5: Ambient and operating conditions - storage