UL Data
Ambient and Operating Conditions - UL Ratings
Description
Sym‐
bol
Unit HCQ02.1E-W0025-_-03
X5.1 X5.2 X5.3 X5.4
Short circuit current rating (UL) SCCR A rms 42000
Rated input voltage, power (UL)
1)
U
LN_nen
n
V 3 x AC 200...500
Rated input current (UL)
I
LN
A 44,0
Output voltage (UL)
U
out
V 3 x AC 0...500
Continuous output current at f
s
= 4 kHz
I
out_cont
4
A 35,0 20,0 14,0
Last modification: 2009-10-21
1) DC bus L+, L-; mains input L1, L2, L3
Fig.5-3: HCQ - Ambient and Operating Conditions - UL Ratings
Information on Standards
Applied Standards
Description Symbol Unit HCQ02.1E-W0025-_-03
Listing according to UL standard
(UL)
UL 508 C
UL files (UL) E 134201
Listing according to CSA standard
(UL)
Canadian National Standard(s) C22.2 No. 14-10
Last modification: 2011-03-30
Fig.5-4: HCQ - Applied Standards
Mechanical System and Mounting
Dimensions, Mass, Insulation, Sound Pressure Level
For the dimensional drawing of the drive controller, see index entry "Dimen‐
sional drawing".
Data for Mass, Dimensions, Sound Pressure Level, Insulation
Description Symbol Unit HCQ02.1E-W0025-_-03
Mass m kg 11,70
Device height (UL)
1)
H mm 455
Device depth (UL)
2)
T mm 191
Device width (UL)
3)
B mm 320
Insulation resistance at DC 500 V
R
is
Mohm 8,00
Last modification: 2010-05-26
Bosch Rexroth AG DOK-INDRV*-HCQ-T+HMQ-T-PR03-EN-P
Rexroth IndraDrive Drive Controllers HCQ, HCT
42/145
Technical Data of the Components