Bit Switches
SM 99 D432/D433
D432/D433
Fax Option
Type
C2550/C2530
2
SIP transport setting
0: TCP
1: UDP
This bit switch sets the transport that has
priority for receiving IP Fax data.
This function is activated only when the
sender has both TCP and UDP.
3
CCM connection
0: No CCM connection
1: CCM connection
When "1" is selected, only the connection
call message with H.323 or no tunneled
H.245 is transmitted via CCM.
4
Message reception selection from
non-registered SIP server
0: Answer
1: Not answer
0: This answers the INVITE message from
the SIP server not registered for the
machine.
1: This does not receive the INVITE
message from the SIP server not registered
for the machine and send a refusal message.
5
ECM communication setting
0: No limit for image compression
1: Limit for image compression
0: This does not limit the type of the image
compression with ECM communication.
1: When the other end machine is Ciscco,
this permits the image compression other
than JBIG or MMR with ECM
communication.
6-7
Not used
Do not change these settings.
IP Fax Switch 03 [SP No. 1-111-004]
No. FUNCTION COMMENTS
0
Effective field limitation for G3
standard function information
0: OFF, 1: 4byte (DIS)
Limits the effective field for standard G3
function information.
1
Switching between G3 standard
and G3 non standard
0: Enable switching
1: G3 standard only
Enables/disables switching between G3
standard and G3 non-standard.
2 Not used. Do not change this setting.