SC Tables
SM Appendix 4-63 D037/D038/D040/D041
Appendix:
Service Call
Conditions
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
2. Initialize the HDD partition (SP5-832-007).
3. Replace the HDD.
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
HDD mail transfer error
An error is detected in the HDD at machine initialization.
 Defective HDD
 Power failure during an access to the HDD
873
CTL
B
1. Initialize the HDD partition (SP5-832-008).
2. Replace the HDD.
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
Delete All error 1: HDD
An error is detected while all of the HDD or NVRAM are formatted
physically by the DataOverwriteSecurity Unit (D362).
 DataOverwriteSecurity Unit (SD card) not installed
 Defective HDD
874
CTL
D
1. Install the DataOverwriteSecurity Unit (D362).
2. Replace the HDD.
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
Delete All error 2: Data area
An error is detected while all of the HDD or NVRAM are formatted
logically by the DataOverwriteSecurity Unit (D362).
 The logical format for the HDD fails.
875
CTL
D
Turn the main switch off/on and try the operation again