SC Tables
D037/D038/D040/D041 4-64 SM Appendix
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
Log Data Error
876
CTL
D
An error was detected in the handling of the log data at power on or
during machine operation. This can be caused by switching the
machine off while it is operating.
Log Data Error 1
 Damaged log data file in the HDD
-001
Initialize the HDD with SP5832-004.
Log Data Error 2
 An encryption module not installed
-002
1. Disable the log encryption setting with SP9730-004 ("0" is off.)
2. Install the DESS module.
Log Data Error 3
 Invalid log encryption key due to defective NVRAM data
-003
1. Initialize the HDD with SP5832-004.
2. Disable the log encryption setting with SP9730-004 ("0" is off.)
Log Data Error 4
 Unusual log encryption function due to defective NVRAM data
-004
Initialize the HDD with SP5832-004.
Log Data Error 5
 Installed NVRAM or HDD which is used in another machine
-005
1. Reinstall the previous NVRAM or HDD.
2. Initialize the HDD with SP5832-004.
Log Data Error 99 -099
 Other than the above causes