System Service Mode
SM Appendix 9-29 D037/D038/D040/D041
Appendix:
SP Mode
Tables
2014 [Charge AC Control: Setting]
001 Main Interval: Power ON *ENG
002 Main Interval: Print *ENG
[0 to 2000 / 500 / 1 page/step]
003 Sub: Interval *ENG
[0 to 500 / 10 / 1 page/step]
004 Sub:Thresh Temp *ENG
[0 to 99 / 25 / 1 deg/step]
005 Sub:R-Humid Thresh *ENG
[0 to 99 / 50 / 1 %RH/step]
006 Sub:A-Humid Thresh *ENG
[0 to 99 / 12 / 1 g/m
3
/step]
007 Main:Temp Change Thresh *ENG
[0 to 99 / 10 / 1 deg/step]
008 Main:RH Change Thresh *ENG
[0 to 99 / 50 / 1 %RH/step]
009 Main:AH Change Thresh *ENG
[0 to 99 / 6 / 1 g/m
3
/step]
010 Sub:Temp Change Thresh *ENG
[0 to 20 / 1 / 0.1 deg/step]
011 Sub:RH Change Thresh *ENG
[0 to 50 / 5 / 1 %RH/step]
012 Sub:AH Change Thresh *ENG
[0 to 20 / 1 / 0.1 g/m
3
/step]
013 Non-use Time *ENG
[0 to 1440 / 360 / 10 min/step]
014 Correction Coeff. *ENG
[0 to 2 / 1 / 0.01 kV/mA/step]
2015 [Charge AC Adj: Result]
001 Bk *ENG
002 C *ENG
003 M *ENG
004 Y *ENG
[0 to 9 / 0 / 1 /step]