System Service Mode
SM Appendix 9-199 D037/D038/D040/D041
Appendix:
SP Mode
Tables
[1 to 999 / 60 / 1 min.]
005 Counter Clear Time
Not Used
5414 [Access Mitigation]
001 Mitigation On/Off *CTL
Switches on/off masking of continuously
used IDs and passwords that are
identical.
[0 to 1 / 0 /1]
0: Off
1: On
002 Mitigation Time *CTL
Sets the length of time for excluding
continuous access for identical user IDs
and passwords.
[0 to 60 / 15 / 1 min.]
5415 [Password Attack]
001 Permissible Number *CTL
Sets the number of attempts to attack the
system with random passwords to gain
illegal access to the system.
[0 to 100 / 30 / 1 attempt]
002 Detect Time *CTL
Sets the time limit to stop a password
attack once such an attack has been
detected.
[1 to 10 / 5 / 1 sec.]
5416 [Access Information]
001
Access User Max
Number
*CTL
Limits the number of users used by the
access exclusion and password attack
detection functions.
[50 to 200 / 200 / 1 users]