System Service Mode
D037/D038/D040/D041 9-200 SM Appendix
002
Access Password Max
Number
*CTL
Limits the number of passwords used by
the access exclusion and password
attack detection functions.
[50 to 200 / 200 / 1 passwords]
003 Monitor Interval *CTL
Sets the processing time interval for
referencing user ID and password
information.
[1 to 10 / 3 / 1 sec.]
5417 [Access Attack]
001
Access Permissible
Number
*CTL
Sets a limit on access attempts when an
excessive number of attempts are
detected for MFP features.
[0 to 500 / 100 / 1]
002 Attack Detect Time *CTL
Sets the length of time for monitoring the
frequency of access to MFP features.
[10 to 30 / 10 / 1 sec.]
003 Productivity Fall Wait *CTL
Sets the wait time to slow down the
speed of certification when an excessive
number of access attempts have been
detected.
[0 to 9 / 3 / 1 sec.]
004 Attack Max Number *CTL
Sets a limit on the number of requests
received for certification in order to slow
down the certification speed when an
excessive number of access attempts
have been detected.
[50 to 200 / 200 /1 attempt]
[User Authentication]
5420
These settings should be done with the System Administrator.
Note: These functions are enabled only after the user access feature has