010
RCG Read Timeout
Sets the length of time (seconds) for the timeout when sent data is written from the RCG
during a call over the @Remote network.
[1 to 100 / 60 / 1 second /step]
011
Port 80 Enable
Controls if permission is given to get access to the SOAP method over Port 80 on the
@Remote network.
[0 or 1 / 0 / – ]
0: No. Access denied
1: Yes. Access granted.
012
@Remote Communication Permission Setting
[0 to 2 / 1 / 1 /step]
013
RFU Timing
Selects the timing for the remote firmware updating.
[0 or 1 / 1 / – ]
0: Any status of a target machine
1: Sleep or panel off mode only
014
[0 or 1 / 0 / 1/step]
021
RCG-C Registed
This SP displays the RCG-N installation end flag.
0: Installation not completed
1: Installation completed
023
Connect Type (N/M)
This SP displays and selects the RCG-N connection method.
[0 or 1 / 0 / 1 /step]
0: Internet connection
1: Dial-up connection
061 Cert Expire Timing DFU
Proximity of the expiration of the certification.
[0 to 0xffffffff / 0 / 1 /step]