5856
[Remote ROM Update]
Allows the technician to upgrade the firmware using a local port (IEEE1284) when
updating the remote ROM.
002 Local Port *CTL
[0 to 1 / 0 / 1/step]
0: Disable
1: Enable
5857 [Save Debug Log] *CTL -
001
On/Off (1:ON 0:OFF) 0: OFF, 1: ON
Switches the debug log feature on and off. The debug log cannot be captured until this
feature is switched on.
002
Target (2: HDD 3: SD) 2: HDD, 3: SD Card
Selects the storage device to save debug logs information when the conditions set with
SP5-858 are satisfied.
[ 2 to 3 / 2 / 1 /step]
005
Save to HDD
Saves the debug log of the input SC number in memory to the HDD.
A unique file name is generated to avoid overwriting existing file names on the SD Card.
Up to 4MB can be copied to an SD Card. 4 MB segments can be copied one by one to
each SD Card.
006
Save to SD Card
Saves the debug log of the input SC number in memory to the SD card.
009 Copy HDD to SD Card(Latest 4MB)
010 Copy HDD to SD Card(Latest 4MB Any Key)
011 Erase HDD Debug Data
012 Erase SD Card Debug Data
013 Free Space on SD Card
014 Copy SD to SD(Latest 4MB)
015 Copy SD to SD(Latest 4MB Any Key)
3. SP Mode Tables