019 By-pass: Small *ENG [-5 to 5 / -2 / 1mm/step]
1101
[Reload Permit Setting]
Specifies the settings of the reload permit for cold temperature in color mode.
001 Pre-rotation Start Temp. *ENG [0 to 200 / 0 / 1deg/step]
002 Reload Target Temp.:Center *ENG [0 to 180 / 175 / 1deg/step]
003 Reload Target Temp.:Press *ENG [0 to 200 / 100 / 1deg/step]
004 Temp.:Delta:Cold:Center *ENG [0 to 200 / 75 / 1deg/step]
005 Temp.:Delta:Cold:End *ENG [0 to 200 / 100 / 1deg/step]
006 Temp.:Delta:Cold:Press *ENG [0 to 200 / 45 / 1deg/step]
007 Rotation Time:Cold *ENG [0 to 200 / 0 / 1sec/step]
008 Temp.:Delta:Warm:Center *ENG [0 to 200 / 85 / 1deg/step]
009 Temp.:Delta:Warm:End *ENG [0 to 200 / 100 / 1deg/step]
010 Temp.:Delta:Warm:Press *ENG [0 to 200 / 45 / 1deg/step]
011 Rotation Time:Warm *ENG [0 to 200 / 0 / 1sec/step]
012 Temp.:Delta:Hot:Center *ENG [0 to 200 / 85 / 1deg/step]
013 Temp.:Delta:Hot:End *ENG [0 to 200 / 110 / 1/step]
014 Temp.:Delta:Hot:Press *ENG [0 to 200 / 45 / 1deg/step]
015 Rotation Time:Hot *ENG [0 to 200 / 0 / 1sec/step]
016 Temp.:Delta:Cold:BW:Center *ENG [0 to 200 / 75 / 1deg/step]
017 Temp.:Delta:Cold:BW:End *ENG -
018 Temp.:Delta:Cold:BW:Press *ENG [0 to 200 / 45 / 1deg/step]
019 Rotation Time:BW:Cold *ENG [0 to 200 / 0 / 1sec/step]
020 Temp.:Delta:Warm:BW:Center *ENG [0 to 200 / 85 / 1deg/step]
021 Temp.:Delta:Warm:BW:End *ENG -
022 Temp.:Delta:Warm:BW:Press *ENG [0 to 200 / 45 / 1deg/step]
3. SP Mode Tables
22