1133
[Last Paper Heater OFF Control]
Sets the time to start turning off the heater after the last paper has fed.
001
Heater OFF Time:Normal
Speed:FC
*ENG [0 to 20000 / 3662 / 1msec/step]
002
Heater OFF Time:Normal
Speed:BW
*ENG [0 to 20000 / 2632 / 1msec/step]
005 Heater OFF Time:Low Speed:FC *ENG [0 to 20000 / 7693 / 1msec/step]
006 Heater OFF Time:Low Speed:BW *ENG [0 to 20000 / 5623 / 1msec/step]
007 Heater OFF Time:After State Shift *ENG [0 to 20000 / 0 / 1msec/step]
1134
[Effective Duty Adjustment]
Switches effective fixed duty level and power control for adjustment.
001 Control Method Switch *ENG
[0 or 1 / 1: ON / 1/step]
0: OFF
1: ON
1141
[Fusing SC Issue Time Info]
Displays the time when an SC code was issued.
001 SC Number *ENG [0 to 99999 / - / 1/step]
101 Htg Roller Temp1 *ENG [-50 to 260 / -/ 1deg/step]
104 Htg Roller Temp1 *ENG [-50 to 260 / - / 1deg/step]
107 Press Roller Temp Value1 *ENG [-50 to 260 / - / 1deg/step]
108 Press Roller.End Temp Value1 *ENG [-50 to 260 / - / 1deg/step]
151 Htg Roller Temp2 *ENG [-50 to 260 / - / 1deg/step]
154 Htg Roller Temp2 *ENG [-50 to 260 / - / 1deg/step]
157 Press Roller Temp Value2 *ENG [-50 to 260 / - / 1deg/step]
158 Press Roller.End Temp Value2 *ENG [-50 to 260 / - / 1deg/step]
201 Htg Roller Temp3 *ENG [-50 to 260 / - / 1deg/step]
Main SP Tables-1