001 HL:K *ENG
Displays TD sensor sensitivity calculated with
check value of HST density control (SP3711-
xxx to 3714-xxx).
[0.200 to 1.000 / - / 0.001-V/wt%/step]
002 HL:C *ENG
003 HL:M *ENG
004 HL:Y *ENG
011 HM:K *ENG
[0.050 to 1.000 / - / 0.001-V/wt%/step]
012 HM:C *ENG
013 HM:M *ENG
014 HM:Y *ENG
021 ML:K *ENG
022 ML:C *ENG
023 ML:M *ENG
024 ML:Y *ENG
031 Upper Limit *ENG
Sets sensitivity upper limit using TD sensor
sensitivity calculation.
[0.200 to 0.500 / 0.440 / 0.001-V/wt%/
step]
032 Lower Limit *ENG
Sets sensitivity lower limit using TD sensor
sensitivity calculation.
[0.200 to 0.500 / 0.209 / 0.001-V/wt%/
step]
033 TC Between H-M *ENG
Sets the TC between H and M using TD sensor
sensitivity calculation.
[1.00 to 10.00 / 2.89 / 0.01wt%/step]
034 TC Between M-L *ENG
Sets the TC between M and L using TD sensor
sensitivity calculation.
[1.00 to 10.00 / 3.00 / 0.01wt%/step]
035 TC Between H-M:K *ENG [1.00 to 10.00 / 2.45 / 0.01wt%/step]
036 TC Between M-L:K *ENG [1.00 to 10.00 / 2.58 / 0.01wt%/step]
3. SP Mode Tables
184