011 Jam Detection: Time Length *CTL
Sets the time a jam must remain before it
becomes an “unattended paper jam”. This
setting is enabled only when SP5508-004
is set to "1".
[3 to 30 / 10 / 1min./step]
012
Jam Detection: Continuous
Count
*CTL
Sets the number of consecutive paper jams
required to initiate a call. This setting is
enabled only when SP5508-004 is set to
"1".
[2 to 10 / 5 / 1/step]
013 Door Open: Time Length *CTL
Sets the length of time the door remains
open before the machine initiates a call.
This setting is enabled only when
SP5-508-004 is set to "1".
[3 to 30 / 10 / 1min./step]
5515
[SC/Alarm Setting] *CTL -
With @Remote in use, these SP codes can be set to issue an SC call when an SC error
occurs. If this SP is switched off, the SC call is not issued when an SC error occurs.