023
Connect Type (N/M) *CTL
[0 or 1 / 0 / 1/step]
0: Internet connection
1: Dial-up connection
This SP displays and selects the RCG-N connection method.
061
Cert Expire Timing *CTL [0 to 0xffffffff / 0 / 1/step] DFU
Proximity of the expiration of the certification.
062
Use Proxy *CTL
[0 or 1 / 0 / 1/step]
0: Not use
1: Use
This SP setting determines if the proxy server is used when the machine communicates
with the service center.
063
Proxy Host *CTL [up to 127 / - / 1/step]
This SP sets the address of the proxy server used for communication between the RCG
device and the gateway. Use this SP to set up or display the customer proxy server
address.
The address is necessary to set up the embedded RCG-N.
• The address display is limited to 128 characters. Characters beyond the 128
character are ignored.
• This address is customer information and is not printed in the SMC report.
064
Proxy Port Number *CTL
[0 to 0xffff / 0 / 1/step]
This SP sets the port number of the proxy server used for communication between the
embedded RCG-N and the gateway. This setting is necessary to set up the embedded
RC Gate-N.
• This port number is customer information and is not printed in the SMC report.
Main SP Tables-5