008
RCG Connect Timeout *CTL [1 to 90 / 30 / 1second/step]
Sets the length of time (seconds) for the time-out when the RCG (Remote Communication
Gate) connects during a call via the @Remote network.
009
RCG Write Timeout *CTL [0 to 100 / 60 / 1second/step]
Sets the length of time (seconds) for the time-out when sent data is written to the RCG
during a call over the @Remote network.
010
RCG Read Timeout *CTL [0 to 100 / 60 / 1second/step]
Sets the length of time (seconds) for the timeout when sent data is written from the RCG
during a call over the @Remote network.
011
Port 80 Enable *CTL
[0 or 1 / 0 / 1/step]
0: No. Access denied
1: Yes. Access granted.
Controls if permission is given to get access to the SOAP method over Port 80 on the
@Remote network.
013
RFU Timing *CTL
[0 or 1 / 1 / 1/step]
0: Any status of a target machine
1: Sleep or panel off mode only
Selects the timing for the remote firmware updating.
014
RCG Error Cause CTL
[0 or 1 / 0 / 1/step]
0: Initial state, normal condition
1: Error
Displays RCG connection error. cause
021
RCG-C Registed *CTL
[0 or 1 / 0 / 1/step]
0: Installation not completed
1: Installation completed
This SP displays the RCG-N installation end flag.