154
Outside Line Outgoing Number *CTL [4digits / - / 1digit/step]
The SP sets the number that switches to PSTN for the outside connection for embedded
RCG-M in a system that employs a PBX (internal line).
If the execution of SP5816-151 has succeeded and embedded RCG-M has
connected to the external line, this SP display is completely blank.
If embedded RCG-M has connected to an internal line, then the number of the
connection to the external line is displayed.
If embedded RCG-M has connected to an external line, a comma is displayed with
the number. The comma is inserted for a 2 sec. pause.
The number setting for the external line can be entered manually (including
commas).
155
156
Dial Up User Name *CTL [up to 32 char. / - / 1char/step]
Use this SP to set a user name for access to remote dial up. Follow these rules when
setting a user name:
Name length: Up to 32 characters
Spaces and # allowed but the entire entry must be enclosed by double quotation
marks (").
157
Dial Up Password *CTL [- / - / -]
Use this SP to set a password for access to remote dial up. Follow these rules when
setting a user name:
Name length: Up to 32 characters
Spaces and # allowed but the entire entry must be enclosed by double quotation
marks (").
161
Local Phone Number *CTL [up to 24 / - / 1/step]
Use this SP to set the telephone number of the line where embedded RCG-M is
connected. This number is transmitted to and used by the Call Center to return calls. Limit: