162
Connection Timing Adjustment
Incoming
*CTL [0 to 24 / 1 / 1/step]
When the Call Center calls out to an embedded RCG-M modem, it sends a repeating ID
tone (*#1#). This SP sets the time the line remains open to send these ID tones after the
number of the embedded RCG-M modem is dialed up and connected.
The actual amount of time is this setting x 2 sec. For example, if you set "2" the line will
remain open for 4 sec.
163
Access Point *CTL [up to 16 / 0 / 1/step]
This is the number of the dial-up access point for RCG-M. If no setting is done for this SP
code, then a preset value (determined by the country selected) is used.
Default: 0
Allowed: Up to 16 alphanumeric characters
164
Line Connecting *CTL
[0 to 1 / 0 / 1/step]
0: Sharing Fax
1: No Sharing Fax
This SP sets the connection conditions for the customer. This setting dedicates the line to
RCG-M only, or sets the line for sharing between RCG-M and a fax unit.
• If this setting is changed, the copier must be cycled off and on.
• SP5816 187 determines whether the off-hook button can be used to interrupt a
RCG-M transmission in progress to open the line for fax transaction.
173
Modem Serial No. *CTL
[- / - / -]
This SP displays the serial number registered for the RCG-M.
174
Retransmission Ringing CTL
[- / - / -]
[Execute]
Normally, it is best to allow unlimited time for certification and ID2 update requests, and
for the notification that the certification has been completed. However, RCG-M
generates charges based on transmission time for the customer, so a limit is placed upon
the time allowed for these transactions.
If these transactions cannot be completed within the allowed time, do this SP to cancel
the time restriction.