187
FAX TX Priority *CTL
[0 or 1/ 0 / 1/step]
0: Disable, 1: Enable
This SP determines whether pushing the off-hook button will interrupt a RCG-M
transmission in progress to open the line for fax transaction. This SP can be used only if
SP5816 164 is set to "0".
200 Manual Polling *CTL
[0 or 1 / 0 / 1/step]
0: Disable, 1: Enable
201
Regist Status CTL [0 to 4 / 0 / 1/step]
Displays a number that indicates the status of the @Remote service device.
0: Neither the registered device by the external nor embedded RCG device is set.
1: The embedded RCG device is being set. Only Box registration is completed. In this
status, this unit cannot answer a polling request from the external RCG.
2. The embedded RCG device is set. In this status, the external RCG unit cannot answer
a polling request.
3. The registered device by the external RCG is being set. In this status the embedded
RCG device cannot be set.
4 The registered module by the external RCG has not started.
202
Letter Number *CTL [- / - / -]
Allows entering the number of the request needed for the RCG-N device.
203
Confirm Execute CTL
[- / - / -]
[Execute]
Executes the inquiry request to the @Remote GW URL.
3. SP Mode Tables
324