001 (0:Light 1:Full) *CTL
[0 or 1 / 0 / 1/step]
0:Light 1:Full
5985
[Device Setting]
Enables/disables the on-board device.
001
On Board NIC CTL
[0 to 2 / 0 / 1/step]
0: Disable, 1: Enable,
2: Function limitation
When the "Function limitation" is set, "On board NIC" is limited only for the NRS or
LDAP/NT authentication.
• Other network applications than NRS or LDAP/NT authentication are not available
when this SP is set to "2".Even though you can change the initial settings of those
network applications, the settings do not work.
002 On Board USB CTL
[0 or 1 / 0 / 1/step]
0: Disable, 1: Enable
5987 [Mech. Counter]
001
0: OFF / 1: ON *ENG [0 or 1 / 0 / 1/step]
This SP detects that a mechanical counter device is removed. If it is detected, SC610
occurs.
5990
[SP Print Mode]
Prints out the SMC sheets.
3. SP Mode Tables