007
Print Ready:Center *ENG [0 to 180 / 150 / 1deg/step]
Specifies the temperature of the heating roller for the print ready condition.
1108 [After Reload/Job Target Temp.] DFU
001
Center *ENG [0 to 180 / 150 / 1deg/step]
Specifies the temperature of the heating roller after re-load or job.
1111 [Environment Correction:Fusing] DFU
001
Temp.:Threshold: Low *ENG [0 to 100 / 17 / 1 deg/step]
Specifies the threshold temperature for low temperature. If the fusing temperature is
17°C or less, the machine executes the fusing mode for low temperature.
002
Temp.:Threshold: High *ENG [0 to 100 / 30 / 1 deg/step]
Sepcifies the threshold temperature for high temperature. If the fusing temperature is
30°C or more, the machine executes the fusing mode for high temperature.
003
Low Temp. Correction *ENG [0 to 100 / 5 / 1 deg/step]
Specifies the additional temperature for the target temperature. If the fusing temperature
is in low temperature condition, this temperature is added to the target temperature.
004
High Temp. Correction *ENG [0 to 100 / 0 / 1 deg/step]
Specifies the additional temperature for the target temperature. If the fusing temperature
is in high temperature condition, this temperature is added to the target temperature.
005 Job Low Temp. Correction *ENG [0 to 100 / 5 / 1 deg/step]
006 Job High Temp. Correction *ENG [0 to 100 / 0 / 1 deg/step]
007 Job Low Temp. Correction:Sp. *ENG [0 to 100 / 5 / 1 deg/step]
008 Job High Temp. Correction:Sp. *ENG [0 to 100 / 0 / 1 deg/step]
011 Standard Environment Temp. *ENG [10 to 30 / 23 / 1 deg/step]
1113 [Curl Correction]
001
Execute Pattern *ENG [0 or 1 / 0:OFF / 1/step]
Selects the curl correction type.
5. System Maintenance
340