002
DFU
Pre-idling Time *ENG [0 to 999 / 300 / 1sec/step]
Specifies the fusing rotation time before executing SP1152-001.
003
DFU
Stop Time *ENG [0 to 100 / 20 / 1sec/step]
Specifies the time for measuring the nip.
004
DFU
Feed Time *ENG [0 to 10000 / 8316 / 1msec/step]
1153 [Low Temp. Start Up]
001
Temp.:Threshold Value1 *ENG [-100 to 100 / -100 / 1deg/step]
Sepcifies the threshold temperature 1 for the warming up in the low temperature
condition.
002
Temp.:Threshold Value2 *ENG [-100 to 100 / -100 / 1deg/step]
Sepcifies the threshold temperature 2 for the warming up in the low temperature
condition.
003
Temp.:Target *ENG [-100 to 100 / -100 / 1deg/step]
Sepcifies the target temperature for the warming up in the low temperature condition.
005
Temp.:Rotation Threshold Value1 *ENG [-100 to 100 / -100 / 1deg/step]
Sepcifies the threshold temperature 1 for the warming up rotation in the low temperature
condition.
010
Time:Heat Storage Devision1 *ENG [0 to 1000 / 0 / 1sec/step]
Sepcifies the execution time 1 for the warming up in the low temperature condition.
011
Time:Heat Storage Devision2 *ENG [0 to 1000 / 0 / 1sec/step]
Sepcifies the execution time 2 for the warming up in the low temperature condition.
1801
[Motor Speed Adjust]
Adjusts the speeds of each motor.
001 transportM:Plain1/2 *ENG [-4.00 to 4.00 / 0.00 / 0.01%/step]
002 transportM:Thin *ENG [-4.00 to 4.00 / 0.00 / 0.01%/step]
5. System Maintenance