1141
[Fusing SC Issue Time Info]
Displays the time when an SC code was issued.
001 SC Number *ENG Displays the issued SC number.
101 Htg Roller:Ctr Diff1 *ENG [-50 to 260 / - / 1deg/step]
104 Htg Roller:End Diff1 *ENG [-50 to 260 / - / 1deg/step]
107 Press Roller Temp Value1 *ENG [-50 to 260 / - / 1deg/step]
108 Press Roller.End Temp Value1 *ENG [-50 to 260 / - / 1deg/step]
151 Htg Roller:Ctr Diff2 *ENG [-50 to 260 / - / 1deg/step]
154 Htg Roller:End Diff2 *ENG [-50 to 260 / - / 1deg/step]
157 Press Roller Temp Value2 *ENG [-50 to 260 / - / 1deg/step]
158 Press Roller.End Temp Value2 *ENG [-50 to 260 / - / 1deg/step]
201 Htg Roller:Ctr Diff3 *ENG [-50 to 260 / - / 1deg/step]
204 Htg Roller:End Diff3 *ENG [-50 to 260 / - / 1deg/step]
207 Press Roller Temp Value3 *ENG [-50 to 260 / - / 1deg/step]
208 Press Roller.End Temp Value3 *ENG [-50 to 260 / - / 1deg/step]
1142 [Fusing Jam Detection]
001
SC Display *ENG
[0 to 1 / 0: OFF / 1/step]
0:OFF, 1:ON
Enables or disables the fusing consecutive jam (three times) SC detection.
1152
[Fusing Nip Band Check]
Checks and adjusts the nip of the hot roller and pressure roller.
001
Execute *ENG -
Executes the nip band measurement between heating roller and pressure roller.
If the nip band width is not 8 mm, and fusing is not good, replace the pressure roller or
install a new fusing unit.
Main SP Tables-1
343