1124
[CPM Down Setting] DFU
Specifies the settings for the CPM down mode.
001
Low:Down Temp. *ENG [-50 to 0 / -20 / 1 deg/step]
Specifies the CPM down threshold temperature for the low temperature condition. If the
fusing temperature decreases -20°C (adjustable) below the target temperature, the
machine enters the CPM down mode.
002
Low:Up Temp. *ENG [-50 to 0 / -15 / 1 deg/step]
Specifies the CPM up threshold temperature for the low temperature condition. If the
fusing temperature increases -15°C (adjustable) below the target temperature, the
machine enters the CPM up mode.
003
Low :1st CPM *ENG [10 to 100 / 80 / 1 %/step]
Specifies the 1st CPM down ration against the normal CPM in the low temperature
condition.
004
Low :2nd CPM *ENG [10 to 100 / 65 / 1 %/step]
Specifies the 2nd CPM down ration against the normal CPM in the low temperature
condition.
005
Low :3rd CPM *ENG [10 to 100 / 50 / 1 %/step]
Specifies the 3rd CPM down ration against the normal CPM in the low temperature
condition.
018
Judging Interval *ENG [0 to 250 / 10 / 1sec/step]
Specifies the interval for CPM down judgment.
1131
[Continuous Print Mode Switch] DFU
Sets the permission for paper to feed.
001 Feed Permit Condition Setting *ENG
[0 to 2 / 0: Productivety Mode / 1/
step]
0: Productivety Model
1: Fusing Quality 1
2: Fusing Quality 2
5. System Maintenance