2104
[Unit LD Power Adj.]
Adjusts the LD initial power. These SPs must be input only when a new laser unit is
installed.
001 Bk *ENG
[60.0 to 140.0 / 100.0 / 0.1%/step]
002 Ma *ENG
003 Cy *ENG
004 Ye *ENG
2105
[LD Power Adj.]
Adjusts the LD power of each color for each process speed.
Each LD power setting is decided by process control.
001 High Speed: Bk *ENG [60.0 to 140.0 / 100.0 / 0.1%/step]
002 High Speed: Ma *ENG
[50 to 120 / 100 / 1%/step]
003 High Speed: Cy *ENG
004 High Speed: Ye *ENG
009 Low Speed: Bk *ENG
010 Low Speed: Ma *ENG
011 Low Speed: Cy *ENG
012 Low Speed: Ye *ENG
2106
[Polygon Rotation Time]
Adjusts the time of the polygon motor rotation.
001 Warming-Up *ENG [0 to 60 / 10 / 1sec/step]
002 Job End *ENG [0 to 60 / 0 / 1/step]
2107
[Image Parameter]
Adjusts image parameters.
001 Warming-Up *ENG [0 or 1 / 1 / 1/step]