002 Forced Setting *ENG
Sets the environment condition manually.
[0 to 6 / 0 / 1/step]
0: Automatic environment control
1: LL (Low temperature/ Low humidity)
2: ML (Middle temperature/ Low humidity)
3: MM (Middle temperature/ Middle
humidity)
4: MH (Middle temperature/ High
humidity)
5: HH (High temperature/ High humidity)
003 Absolute Humidity:Threshold 1 *ENG
Adjusts the threshold value between LL and
ML.
[0.00 to 100.00 / 4.00 / 0.01g/m
3
/
step]
004 Absolute Humidity:Threshold 2 *ENG
Adjusts the threshold value between ML
and MM.
[0.00 to 100.00 / 8.00 / 0.01g/m
3
/
step]
005 Absolute Humidity:Threshold 3 *ENG
Adjusts the threshold value between MM
and MH.
[0.00 to 100.00 / 16.00 / 0.01g/m
3
/
step]
006 Absolute Humidity:Threshold 4 *ENG
Adjusts the threshold value between MH
and HH.
[0.00 to 100.00 / 24.00 / 0.01g/m
3
/
step]
007 Temperature:Threshold *ENG [-5 to 30 / 5 / 1deg/step]
2308
[Paper Size Correction]
Adjusts the threshold value for the paper size correction.
001 Threshold 1 *ENG
[0 to 250 / 194 / 1mm/step]
Threshold 1 ≤ paper: Paper is detected as
"S1" size.
Main SP Tables-2