031 ON Time *ENG
Sets the supply ON or OFF time of each supply
in the forced toner supply processing routin.
[10 to 1000 / 200 / 1msec/step]
032 OFF Time *ENG
Sets the supply ON or OFF time of each supply
in the forced toner supply processing routin.
[10 to 1000 / 100 / 1msec/step]
033 RepeatCount *ENG
Sets the repeat count in the forced toner supply
processing routin.
[0 to 255 / 8 / 1times/step]
3072 [TD.Sens Check: Exe]
001 All Colors ENG
Execute TD sensor check for all colors.
[Execute]
3073 [TD.Sens Chk]
001 Disp Vt:K *ENG
Displays the measurement with the TD sensor
check.
[0 to 5.5 / - / 0.01V/step]
002 Disp Vt:C *ENG
003 Disp Vt:M *ENG
004 Disp Vt:Y *ENG
3074 [ID.Sens Check :Exe]
001 All Sensors ENG
Execute ID sensor check for all sensors.
[Execute]
3075 [ID.Sens Chk]
Main SP Tables-3
403