002 Rel Humidity *ENG
Displays the relative humidity at the end of the
image processing.
[0.0 to 1000.0 / - / 0.1%RH/step]
003 Abs Humidity *ENG
Displays the absolute humidity at the end of the
image processing.
[0.0 to 1000.0 / - / 0.1gm3/step]
3529 [ProCon Interval Control :Set]
001 Gamma Corr *ENG Sets on/off for the developer gamma
correction or the environment correction of
process control execution interval.
[0 or 1 / 1 / 1/step]
0:OFF, 1:ON
002 Environ Corr *ENG
003 AbsHum Threshhold *ENG
Sets absolute humidity threshold for the
environment correction of process control
execution interval.
[0.0 to 99.0 / 4.3 / 0.1g/m3/step]
004 Max Cnt Threshhold *ENG
Sets the maximum number of times for interuppt
or job end process control.
[0 to 99 / 2 / 1counts/step]
005 Exe Cnt *ENG
Displays the maximum counter for interuppt or
job end process control.
[0 to 255 / - / 1 counts/step]
006 Page Cnt:BW *ENG
Displays the page counter of process control.
[0 to 5000 / - / 1sheets/step]
007 Page Cnt:FC *ENG
3530 [PowerON ProCon :Set]
001 Non-use Time Setting *ENG
Sets the threshold for process control execution
determination at power on.
[0 to 1440 / 360 / 1minute/step]
002 Temperature Range *ENG
Sets the threshold for process control execution
determination at power on.
[0 to 99 / 10 / 1deg/step]
5. System Maintenance